HomeProducts Select by Industry Building Component Testing Equipment Fire Retardant Paints Burning Test Apparatus (Tunnel Method)
Fire Retardant Paints Burning Test Apparatus (Tunnel Method)
  • Fire Retardant Paints Burning Test Apparatus (Tunnel Method)
Fire Retardant Paints Burning Test Apparatus (Tunnel Method)

Fire Retardant Paints Burning Test Apparatus (Tunnel Method)

this machine Conform to ASTM D3806 standard Applicable to the determination of flame propagation performance of decorative fire retardant paints.


Product Number:ZY6240
Share:
  • Product Description

1. Scope of application:

1.1 It is suitable for testing the flame propagation characteristics of fire retardant paints painted on the surface of burning substrates with a small tunnel furnace under laboratory conditions.

1.2 Applicable to the determination of flame propagation performance of decorative fire retardant paints


2. Compliant standards:

2.1. Conform to ASTM D3806 standard


3. The main technical parameters:

3.1 Tunnel furnace:

3.1.1 It is composed of angle steel frame and ceramic fiber board (asbestos cement board).

3.1.2 The angle steel frame is welded by 35 mm<30 100="" 610="" mmx2="" mm="" angle="" steel.="" the="" top="" of="" steel="" frame="" is="" long="" and="" wide="">

3.1.3 The flue end of the tunnel furnace is open; there is an air supply hole with a diameter of 25 mm at the center of the bottom of the tunnel furnace 110 mm away from the base.

3.1.4 The observation window of the heat-resistant glass plate is located under the side of the specimen support, and is made of a piece of quartz glass or heat-resistant laurel glass with a length of 622 m, a width of 50 mm, and a thickness of 3 mm. Mark the glass from 100 mm to 500 mm at one end at intervals of 25 mm. Above the observation window is a metal sunshade that slopes down 60°. Inside the specimen holder is a serrated stainless steel calibration plate with a pitch of 25 mm.

3.1.5 On the side of the test plate support, above the centerline of the burner, there is a thermocouple insertion hole with a diameter of 3 mm, so that the hot junction of the thermocouple is delivered to the back fire surface of the test piece.

3.1.6 The tunnel furnace should be placed in a room without forced ventilation.

3.2 Burner:

3.2.1 Burner: made of brass, with a top diameter of 20mm and a height of about 200mm. Gas burner with adjustable air intake.

3.2.2 Fuel: Gas with purity over 95%.

3.2.3 Igniter: It is a high-voltage electronic automatic ignition.

3.3 Cover plate: It is composed of heat-insulating asbestos board and steel plate pressed on the asbestos board, and its dimensions are 600 mm in length, 90 mm in width and 10 mm in thickness.

3.4 Temperature monitoring instrument:

3.4.1 The flame center temperature is measured by armored thermocouples with an accuracy of class II, type K, and an outer diameter of 2.0 mm. Range 1300°C.

3.4.2 Temperature record: Imported intelligent P.I.D temperature controller (with automatic calculation function) and high-precision PT100 thermocouple sensor and timer are adopted, with an accuracy of 0.5%±1.

3.5 Timer: 0~99.99s can be set arbitrarily, resolution: 0.01s, error: 1s/h

3.6 Automatic buzzer: During the test, an alarm will be issued every 15 seconds to remind the operator to record the current combustion status, and the combustion time lasts for 4 minutes.

3.7 Test station: 1 station.

3.8 Sample size: L900*W900 thickness is 5mm, the surface is flat and smooth. The standard requirements that the sample must meet: 1. The asbestos standard plate is 600*90, and the thickness is 6-8mm. 2. The standard board of rubber wood is 600*90, and the thickness is 8-10mm.

3.9 Gas flow: 860ml/min adjustable.

3.10 Flame temperature: 900℃±2℃

3.11 The structure of the instrument consists of two major parts, the main control box and the combustion box. The control box is removable.

3.12 Combustion box size: 610㎜×250㎜×520㎜.

3.13 The frame material is welded by high-quality stainless steel, the control box is made of electrostatic steel plate, and the surface is sprayed with plastic, which is more clean and beautiful.

3.14 The control box adopts a relay control system, and all electronic components are domestic leading brands, which can better guarantee the working performance and detection accuracy of the machine.

3.15 The equipment has the following safety protection devices: power overload, short circuit protection, control circuit overload protection, and ultra-high temperature protection.

3.16 Power requirements: AC220 (±10%) V/50HZ

3.17 The standard board is equipped with:

3.17.1 Asbestos standard board: the size is 600 mm in length, 90 mm in width and 6 mm to 8 mm in thickness.

3.17.2 Oak standard board: 600 mm in length, 90 mm in width, 8 mm to 10 mm in thickness, and its air-dry density is (0. 7 to 0. 85) g/cm3.

3.18 Test substrate: The test substrate is a first-grade five-layer plywood with a thickness of (5±0.2) mm. The test plate is 600 mm long and 90 mm wide. The surface of the test panel should be flat and smooth, without knots and obvious defects.

fire retardant paints burning test apparatus tunnel method zonsky


Email to this supplier
  • To:
    ZONSKY INSTRUMENT CO., LTD
  • *E-mail:
  • *Message:

    Your message must be between 20-8000 characters

HomeProducts Select by Industry Building Component Testing Equipment Fire Retardant Paints Burning Test Apparatus (Tunnel Method)

Home

Product

Phone

About Us

Inquiry