Electrical fire arc test machine Simulate the ignition process caused by electric circuit arc and the cause of fire formation.
1. Overview:
1.1 Applicable to experimental teaching for electrical fire simulation experiments;
1.2 Experimental items:
(1) Single-phase short-circuit fault;
(2) Two-phase short circuit fault;
(3) Overcurrent fault;
(4) Secondary phase-to-phase short circuit fault induced by overcurrent fault;
(5) Plug and socket overcurrent fault;
(6) Local overheating faults between lines and connectors;
(7) Simulation plug and socket virtual connection heating fault;
(8) Arc fault experiment;
(9) Step voltage test;
(10) Fire caused by contact failure of power distribution control cabinet;
2. Main performance parameters:
2.1. Main components: three parts: physical test chamber, functional simulation experiment and control system;
2.2. Test box: 0.5m3 simulated test box; adopt frame structure, add 1.5mm thick SUS304 electrostatic high-temperature baking varnish; the physical test box is 1.7m3 adopt frame structure, add 1.5mm thick SUS304 plate electrostatic high-temperature baking varnish;
2.3. There is an observation window; high temperature glass is used.
2.3. Test bench: made of insulating and flame-retardant materials;
2.4. Test load: impedance load;
(Please consult us for more complete parameters)