HomeFaq Technology Center

2024-04-09

BS 7177 Code for fire protection of cushions, sofas and mattresses

BS 7177 Code for fire protection of cushions, sofas and mattresses

BS 7177 Fire protection specification for cushions, sofas and mattresses:
BS 7177 specifies the fire performance requirements for cushions, sofas and mattresses in compliance with BS 597-1, BS 597-2 and BS 6807 including those used in areas prone to fire. Fire performance levels are determined by careful consideration of the ultimate fire risk in a particular environment. These ratings do not necessarily reflect the overall fire performance of cushions, sofas and mattresses.
 
BS 7177: Code for fire protection of cushions, sofas and mattresses
BS 7177: Specification for resistance to ignition of mattresses, divans and bed bases
 
Furniture articles specified in BS 7177 : cushions, sofas, mattresses, etc.
 
BS 7177 standard analysis:
Implement requirements and note application to hazardous location categories
Hazard level
Require
Example
Household use
low risk)
Flame retardant fire source - smoldering cigarettes according to BS EN 597-1
Flame retardant fire source - the equivalent flame of a match is in accordance with BS EN 597-2
Family accommodation (including non-motorized caravan)
medium risk
Flame retardant fire source - smoldering cigarettes according to BS EN 597-1
Flame-retardant fire source - the equivalent flame of a match is in accordance with BS EN 597-1. Flame-retardant fire source 5 is in accordance with BS 6807.
day operation center
hostel
Residential old residence
camping cabin
boarding school
University student accommodation
high risk
Flame retardant fire source - smoldering cigarettes according to BS EN 597-1
Flame-retardant fire source - the equivalent flame of a match is in accordance with BS EN 597-1. Flame-retardant fire source 7 is in accordance with BS 6807.
Hospital Nursing Department
Seaside facilities
hostel
Residential old residence
Very high risk
Flame retardant fire source - smoldering cigarettes according to BS EN 597-1
Flame retardant fire source - the equivalent flame of a match is in accordance with BS EN 597-1. Flame retardant fire source 7 is in accordance with BS 6807.
Experimenters’ additional tests must be higher than the high-risk level requirements
prison unit
Closed Rehabilitation Center Residence


BS 7177 related reference standards
   BS 5651: Cleaning and wetting methods for assessing the effect of cleaning and wetting on the flammability properties of textiles and assemblies
   BS 5803: Slope roof space insulation
   BS 5803-1: Thermal insulation of pitched roof spaces of dwellings. Part 1: Specification for man-made mineral fiber thermal insulation mats
   BS EN 597: Furniture - Evaluation of the flammability of mattresses and upholstered bedding.
   BS EN 597-1: Part 1: Source of ignition: smoldering cigarette
   BS EN 597-2: Part 2: Source of ignition: A source of ignition equivalent to a match flame.

Previous: 16 CFR 1632 Mattress Burning Performance Standard